    Home»Alerts»Schneider Electric Modicon M241, M251, and M262
    Alerts

    Schneider Electric Modicon M241, M251, and M262

    adminBy adminMarch 22, 2026No Comments6 Mins Read
    Share Facebook Twitter Pinterest LinkedIn Tumblr Reddit Telegram Email
    Share
    Facebook Twitter LinkedIn Pinterest Email


    View CSAF

    Summary

    Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the product.

    The following versions of Schneider Electric Modicon M241, M251, and M262 are affected:

    • Modicon M241 versions prior to 5.4.13.12 Modicon_Controller_M241
    • Modicon M251 versions prior to 5.4.13.12 Modicon_Controller_M251
    • Modicon M262 versions prior to 5.4.10.12 Modicon_Controller_M262
    CVSS Vendor Equipment Vulnerabilities
    v3 5.3 Schneider Electric Schneider Electric Modicon M241, M251, and M262 Improper Resource Shutdown or Release

    Background

    • Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy
    • Countries/Areas Deployed: Worldwide
    • Company Headquarters Location: France

    Vulnerabilities

    Expand All +

    CVE-2025-13901

    CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.

    View CVE Details


    Affected Products

    Schneider Electric Modicon M241, M251, and M262

    Vendor:
    Schneider Electric

    Product Version:
    Schneider Electric Modicon M241 versions prior to 5.4.13.12: Modicon_Controller_M241, Schneider Electric Modicon M251 versions prior to 5.4.13.12: Modicon_Controller_M251, Schneider Electric Modicon M262 versions prior to 5.4.10.12: Modicon_Controller_M262

    Product Status:
    known_affected

    Remediations

    Mitigation
    Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.
    https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/

    Mitigation
    Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.
    https://www.se.com/ww/en/download/document/EIO0000005500/

    Mitigation
    Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.
    https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/

    Mitigation
    Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.
    https://www.se.com/ww/en/download/document/EIO0000005500/

    Mitigation
    Modicon Controller M262 Firmware version 5.4.10.12 delivered with EcoStruxure™ Machine Expert v2.5 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M262 to the latest Firmware and perform reboot. For instructions refer to Modicon M262 Logic/Motion Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.
    https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/

    Mitigation
    Modicon Controller M262 Firmware version 5.4.10.12 delivered with EcoStruxure™ Machine Expert v2.5 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M262 to the latest Firmware and perform reboot. For instructions refer to Modicon M262 Logic/Motion Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/.
    https://www.se.com/ww/en/download/document/EIO0000005500/

    Mitigation
    For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-01 Improper Resource Shutdown or Release vulnerability in Multiple Products – SEVD-2026-069-01 PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-01.pdf. Improper Resource Shutdown or Release vulnerability in Multiple Products – SEVD-2026-069-01 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-01.json.
    https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-01.pdf

    Mitigation
    All affected products: If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Filter ports and IP through the embedded firewall. Use encrypted communication links. Use VPN (Virtual Private Networks) tunnels if remote access is required. The “Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment” provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242.
    https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242

    Relevant CWE: CWE-404 Improper Resource Shutdown or Release


    Metrics


    Acknowledgments

    • Noam Moshe of Claroty reported this vulnerability to Schneider Electric
    • Schneider Electric reported this vulnerability to CISA

    Legal Notice and Terms of Use

    This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).


    Recommended Practices

    CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

    Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.

    Locate control system networks and remote devices behind firewalls and isolating them from business networks.

    When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

    CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

    CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

    CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

    Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

    Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

    CISA also recommends users take the following measures to protect themselves from social engineering attacks:

    Do not click web links or open attachments in unsolicited email messages.

    Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.

    Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

    No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.


    Revision History

    • Initial Release Date: 2026-03-19
    Date Revision Summary
    2026-03-19 1 Initial Republication of Schneider Electric CPCERT SEVD-2026-069-01

    Legal Notice and Terms of Use



    Source link

    Share. Facebook Twitter Pinterest LinkedIn Tumblr Email
    Previous ArticleVU#458422: CASL Ability contains a prototype pollution vulnerability
    Next Article InfoSec News Nuggets 03/13/2026 – AboutDFIR
    admin
    • Website

    Related Posts

    Alerts

    SSA-734261 V1.0: Authentication Bypass Vulnerability in Energy Services Using Elspec G5DFR

    April 8, 2026
    Alerts

    Incident: Eagers Automotive says IT outage stems from cyber incident | iTnews

    April 8, 2026
    Alerts

    CISA Adds One Known Exploited Vulnerability to Catalog

    April 8, 2026
    Add A Comment

    Comments are closed.

    Demo
    Top Posts

    Global Takedown of Massive IoT Botnets Halts Record-Breaking Cyberattacks

    March 20, 202619 Views

    Catchy & Intriguing

    March 17, 202619 Views

    The Grandparent Scam: How AI Voice Technology Makes This Old Con Deadlier Than Ever

    March 18, 202617 Views
    Stay In Touch
    • Facebook
    • YouTube
    • TikTok
    • WhatsApp
    • Twitter
    • Instagram
    Latest Reviews
    85
    Featured

    Pico 4 Review: Should You Actually Buy One Instead Of Quest 2?

    January 15, 2021 Featured
    8.1
    Uncategorized

    A Review of the Venus Optics Argus 18mm f/0.95 MFT APO Lens

    January 15, 2021 Uncategorized
    8.9
    Editor's Picks

    DJI Avata Review: Immersive FPV Flying For Drone Enthusiasts

    January 15, 2021 Editor's Picks

    Subscribe to Updates

    Get the latest tech news from FooBar about tech, design and biz.

    Demo
    Most Popular

    Global Takedown of Massive IoT Botnets Halts Record-Breaking Cyberattacks

    March 20, 202619 Views

    Catchy & Intriguing

    March 17, 202619 Views

    The Grandparent Scam: How AI Voice Technology Makes This Old Con Deadlier Than Ever

    March 18, 202617 Views
    Our Picks

    Wildlife Cops Are Searching AI Cameras for ICE

    April 8, 2026

    SSA-734261 V1.0: Authentication Bypass Vulnerability in Energy Services Using Elspec G5DFR

    April 8, 2026

    Incident: Eagers Automotive says IT outage stems from cyber incident | iTnews

    April 8, 2026

    Subscribe to Updates

    Get the latest creative news from FooBar about art, design and business.

    Facebook X (Twitter) Instagram Pinterest
    • Home
    • Technology
    • Gaming
    • Phones
    • Buy Now
    © 2026 ThemeSphere. Designed by ThemeSphere.

    Type above and press Enter to search. Press Esc to cancel.